Bac à Orthocollator

MassoKit

Orthocollator Tank

$574.95

Easily and efficiently warm up your thermotherapy cushions with the Orthocollator MassoKit Heating Pad.

Specially designed for our Orthocollators, this device ensures even and hassle-free warming.

Made entirely of high-quality stainless steel, the tray warms and maintains the ideal temperature for your Orthocollators (between 71°C and 74°C). Additionally, it is easy to maintain thanks to its pipeless design and easy refill feature.

Inclus :

  • 4 Standard 10" x 12" Silica Orthocollators
  • 4 separator supports
ONE YEAR WARRANTY

This warranty is effective for one year from the date of purchase by the original customer. In the event of a breakdown during this period, Clinique Lafontaine will repair or replace the product free of charge within a reasonable time.
Any repair must be carried out by our service center. Any modification or repair carried out by another unauthorized service center will void this warranty.
The shipping costs are covered by the customer for shipping to Clinique Lafontaine. During the warranty period, the supplier will return the replaced or repaired product to the user at no cost.
IMPORTANT : This warranty does not cover the wire or the fuse. This warranty does not cover damages resulting from an accident, misuse, abuse, or lack of maintenance. 

Precautions

Do not use the device in an environment where other devices are being used and intentionally emit electromagnetic energy in an unprotected manner. Portable and mobile radiofrequency communication equipment can disrupt medical electrical equipment.

The Orthocollator heating device generates, uses, and can emit radioelectric energy. If it is not installed or used properly, it can cause harmful interference with other nearby devices. Reposition or move the receiving device, increase the distance between the equipment, plug the equipment into an outlet on a different circuit than the one to which the other devices are connected.

Do not use accessories other than those from the same range as Orthocollator or recommended by Clinique Lafontaine. The safety of other products has not been established and their use could harm a customer.

If there is a breakage, always replace it with parts authorized by the factory.

• The device temperature is preset at the factory, so it is ready to use. Never set the thermostat to a too high temperature. The thermostat is extremely sensitive and even the slightest adjustment will change the temperature by several degrees. The recommended operating temperature is between 71° and 74°C (160° to 165°F). The water temperature should be checked with a thermometer after each adjustment.

• Always completely cover the Orthocollator (cushions) with water. Fill with water every day. Water evaporates continuously.

Never let the Orthocollator (cushions) dry out.

• Clean the tank periodically following the instructions (see in MAINTENANCE section).

Always replace worn Orthocollators (cushions).

Disconnect the device, remove the Orthocollators (cushions), drain the water, and clean the tank if the device is not in use for a certain period.

Do not move the device while it is filled with hot water. Its overturning could cause burns.

• Always unplug the device before emptying or filling.

Do not retrieve the Orthocollators (cushions) from the tank with bare hands.

Always wrap the Orthocollators (cushions) in a towel or ideally the cover provided for this purpose.

Monitor the cushion application frequently to ensure that the skin does not get too warm.

Do not apply on desensitized skin or in the presence of poor circulation. Do not use directly on cuts, abrasions, or wounds.

Never lie down or sit on the cushion.

Be extremely careful when using hot pads on individuals who cannot communicate.

Some products added to water (such as certain infusions or essences) can damage the components of the appliance, the thermostat, and stainless steel.

Place the Orthocollators (cushions) in the device before filling it with water.

NOTE : Do not turn the rod inside. The Orthocollator heating device operates with a capillary hydraulic thermostat and can remain plugged in to ensure constant availability of the Orthocollator hot cushion. 

 

Indicators and controls

White lamp: The device is plugged in, the switch is in the ON position, and the device is running.


Red lamp: Warns of overheating or lack of water in the tank. 

 

Important information

This model is equipped with a thermal cut-off thermostat. In case of a malfunction, this thermostat is designed to cut off the electrical circuit between 88°C ± 8° (190°F ± 14°F). It is not possible to modify this setting. The device can be restarted by pressing the red RESET button (on the side of the device) after the water and heating element have cooled down.

This stainless steel heating tank is a device equipped with a thermostat setting to ensure an ideal therapeutic temperature for Orthocollators.

 

  • Reliable and robust design
  • Made of high-quality stainless steel
  • Temperature controlled by a thermostat
  • Easy to use
  • Easy to fill
  • No plumbing required


Benefits of thermotherapy:

  • Relieves joint and muscle stiffness and pain
  • Helps alleviate joint pain associated with osteoarthritis
  • Reduce muscle contractions and soreness
  • Pleasant relaxation effect

Heat therapy is recommended for:

  • Joint and muscle pain
  • Osteoarthritis
  • Muscle contractures and soreness
  • Low back pain, thoracic pain, and neck pain
  • Recovery phase for athletes

Duration of treatment: 30 minutes maximum

 

DURING FIRST USE:

Remove all the contents from inside the heater, then replace the metal rack. The tank should be filled to about 3/4 when the products are not in it. Insert your cushions, plug in the device.

The chlorine present in regular tap water can have a concentration high enough to damage the device. If you are concerned that it contains too much, adding a product aimed at reducing the chlorine concentration is recommended (or using distilled water). 

 

Maintenance

 

Maintenance and cleaning


1. The inside of the appliance should be cleaned at least every two weeks using a mildly abrasive bathroom cleaner and a soft cloth or a Scotch-Brite green, blue, or white cleaning pad. Stainless steel wool can be used if absolutely necessary. Make sure your cleaner contains little to no chlorine and ensure that residues are thoroughly rinsed with water.


2. A strong solution of vinegar and water can be used to dissolve deposits, which should be thoroughly rinsed.


3. To clean the exterior, use only a stainless steel detergent and a soft cloth. The use of any other detergent on the appliance's exterior is not recommended. Abrasive detergents and pads can damage the appliance's coating.

This device is made of high-quality stainless steel which, with proper care and maintenance, can easily last a lifetime. Improper treatment could prematurely wear out the stainless steel.


To avoid the risk of rust


1. Do not use bleach or products containing bleach.


2. Do not use paper clips, pins, staples, hangers, etc. in or near the device.


3. Do not clean the device with glass wool or a carbon steel brush.


4. Do not use abrasive detergents that tend to disrupt the varnish grain, especially on the exterior of the device.


5. Remove all deposits from surfaces and internal parts. Deposits are mineral concentrations that allow rust to settle. Deposits on the heating element reduce its efficiency and cause an increase in electricity consumption.


6. If you think your water is hard, you will need to change the water and clean the appliance more often.


Maintenance of Orthocollator cushions


The cushion can be cleaned by brushing it with soap and water. The simplest method to keep the cushion clean is to leave it covered with water.

When the Orthocollator is worn out, the filling will start to seep through the fabric, some areas will empty, and the Orthocollator will no longer retain its heat properly. When it is in this condition, it must be replaced.

NOTE : Orthocollators can be stored for an extended period - wet - in a plastic bag in the freezer. 

 

Specifications

 

Food: 110-120 V~

Fréquence : 60 Hz

Puissance : 1000W

Tank capacity: 15.44 L

Filled weight: 25 kg (55 lb)

Temperature range: 71°C - 74°C (160º F-165º F)

Circuit breaker temperature: 88°C ± 8° (190°F ± 14°F)

Heating time: Up to 70°C - 160 º F): 2 hours

Cooling time: Return to 70°C - 160 º F: 1 hour

Electrical safety category: Category 1, type B

Security tests: IEN 60601-1

Dimensions : 16"x 13"x 8" (41 cm x 33 cm x 20 cm)

Poids : 6.4 kg (14 lb)

Fusible : Interior, 15 AMP.

4 standard orthocollators included

 

Troubleshooting

The following table provides simple solutions to minor problems. If you have any questions, do not hesitate to contact Clinique Lafontaine. 

 